The main characteristic of this series is the capability to read temperature of the media up to 400°C.
The constructive principle is based on the hydraulic trasmission of the pressure.
The fluid-filled system assures the temperature stability.
The phisical measure is transformed in a electrical measure by means the strain-gauge technology.
Pressure ranges: 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
Extensometric measurement principle with Wheatstone bridge
Precision: <±0.25% FS (H); <±0.5% FS (M)
Calibration signal 80% FS internally generated
Protection level: IP65 (6-pin connector)
Standard threading 1/2-20 UNF, M18x1.5, other versions on request
Standard diaphragm is 15-5 PH stainless steel with GTP+ coating
17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi
Further versions available on request.